Installation and Safety Precautions
Ensure the boiler is installed vertically with minimum clearances: 165mm above, 100mm below, and 2․5mm at the sides․ Use only approved flue kits and genuine parts․
1․1 Key Installation Requirements
The Ideal Logic Combi 30 must be installed vertically with specific clearances: 165mm above, 100mm below, 2․5mm at the sides, and 450mm at the front for servicing access․ Ensure the boiler is fitted in accordance with the installation instructions, using only approved flue kits and genuine spare parts․ Proper clearances ensure safe operation and easy maintenance․ Always follow the manufacturer’s guidelines for electrical connections and gas supply lines․ Compliance with these requirements is essential for optimal performance and safety․ Refer to the manual for detailed installation steps and diagrams․
1․2 Safety Guidelines for Ideal Logic Combi 30
Ensure the boiler is installed vertically by a qualified technician, using only approved flue kits․ Always inspect gas supply lines for leaks before activation․ Maintain proper ventilation and clearances around the boiler to prevent overheating․ Avoid obstructing the appliance or surrounding areas․ Follow all safety instructions in the manual, including guidelines for electrical connections and condensate disposal․ Regularly check for frozen condensate pipes during winter․ Adhere to gas safety regulations and ensure all servicing is performed by certified professionals to maintain optimal performance and safety standards․
Initial Setup and Configuration
Set the clock and timer according to the user manual; Configure heating modes and hot water settings․ Familiarize yourself with the RF programmable thermostat controls for optimized operation․
2․1 First-Time Setup Steps
Begin by ensuring the boiler is installed vertically with proper clearances․ Connect the flue kit as per instructions․ Power on the boiler and set the clock and timer․ Program the RF programmable thermostat to desired settings․ Ensure all gas and water supplies are connected correctly․ Refer to the user manual for detailed configuration steps․ Familiarize yourself with the controls and settings to optimize performance․ Always follow the manual’s guidelines for a safe and efficient setup․
2․2 Clock and Timer Programming
Set the clock by pressing the ‘+’ or ‘-‘ buttons to adjust the time․ Enable the timer by selecting the ‘Timer’ function and choose between automatic or manual modes․ Program heating schedules by specifying start and end times for both heating and hot water․ Use the RF programmable thermostat to set room temperatures․ Ensure the battery is installed correctly for the thermostat to function․ Refer to the user manual for detailed instructions on advanced features and battery replacement․
2․3 Understanding Boiler Controls
The boiler features a mode selector switch for choosing between heating, hot water, or both․ Adjust temperature settings using the dials or digital controls․ The display shows operational status and error codes․ Ensure all controls are set correctly for efficient operation․ Refer to the user manual for detailed instructions on using the RF programmable thermostat and advanced features․ Always use genuine spare parts and follow installation guidelines for optimal performance and safety․
Operating the Boiler
The boiler operates efficiently in condensing mode, providing central heating and hot water․ Use the RF programmable thermostat and ensure controls are set correctly for optimal performance․
3․1 Overview of Boiler Operation
The Ideal Logic Combi 30 is a high-efficiency combination boiler designed to provide both central heating and instantaneous domestic hot water․ It operates in condensing mode for optimal energy efficiency․ The boiler automatically adjusts its output to match demand, ensuring consistent heating and hot water performance․ Controls include a programmable room thermostat and a boiler control panel for temperature and mode adjustments․ The system is designed for ease of use, with clear indicators for operation status and maintenance needs․ Proper installation and setup ensure reliable and efficient operation․
3․2 Heating Modes and Settings
The Ideal Logic Combi 30 offers multiple heating modes to suit various needs․ Eco-mode optimizes energy use by reducing pump speed․ Comfort mode ensures faster heating by increasing circulation․ Normal mode provides balanced efficiency and comfort․ Users can adjust the boiler’s temperature settings via the control panel or optional programmable thermostats․ Time-based scheduling allows for tailored heating programs, enhancing energy efficiency and convenience․ These modes and settings ensure the system adapts seamlessly to household demands, maintaining comfort while minimizing energy consumption․
3․3 Hot Water Settings and Usage
The Ideal Logic Combi 30 provides instant hot water with adjustable temperature controls․ Hot water mode allows presetting desired temperatures up to 65°C for safety and efficiency․ The boiler features a pre-heat function for rapid hot water delivery․ Users can activate the eco-mode to reduce energy consumption without compromising comfort․ Additionally, the system includes a temperature lock to prevent accidental changes․ These settings ensure consistent and efficient hot water supply, catering to household needs while optimizing energy use․ Proper usage enhances both performance and longevity of the boiler․
Troubleshooting Common Issues
Common issues include error codes like F2 (flame loss) and low water pressure․ Check the manual for solutions, such as re-pressurising the system or restarting the boiler․
4․1 Error Codes and Solutions
The Ideal Logic Combi 30 displays error codes like F2 (flame loss) or F1 (low water pressure)․ For F2, check gas supply and ensure the flue is unobstructed․ For F1, re-pressurise the system (refer to manual)․ Other codes may indicate issues like faulty sensors or ignition problems․ Always consult the user manual for specific solutions or contact a certified technician if issues persist․ Regular maintenance can help prevent errors and ensure efficient boiler operation․
Low water pressure in the Ideal Logic Combi 30 can cause issues like reduced heating efficiency or error codes such as F1․ To resolve this, re-pressurise the system by locating the filling loop under the boiler; Open the valves to allow water to flow into the system until the pressure gauge reaches the recommended level (typically between 1-2 bar)․ Ensure all radiator valves are open during this process․ If pressure drops frequently, check for leaks or blockages in the system and consult a professional if needed․ Always follow the user manual for detailed steps․ Regular servicing is essential for optimal performance․ Schedule annual checks with qualified technicians and ensure genuine parts are used for replacements and repairs․ Regular checks ensure optimal performance and safety․ Inspect the flue for blockages, check water pressure (ideal range 1-2 bar), and clean condensate traps․ Annual servicing by a qualified technician is mandatory․ Ensure all components, including the heat exchanger and burner, are free from debris․ Refer to the user manual for detailed steps․ Always use genuine parts for replacements to maintain efficiency and safety standards․ Always use genuine parts for replacements to maintain safety and efficiency․ The boiler must be serviced annually by a qualified technician․ Refer to the servicing schedule in the manual for detailed timelines․ Ensure the heat exchanger and condensate trap are checked and cleaned during servicing․ For specific part replacements, consult the Logic Combi 30 parts list․ A downloadable servicing schedule is available on the Ideal Heating website for easy reference․ Adhere strictly to the manufacturer’s guidelines for all maintenance tasks․ The Logic Combi 30 is a high-efficiency condensing boiler with a 30kW output․ It comes with a 2-5 year warranty, depending on installation and registration․ The Logic Combi 30 is a high-efficiency condensing boiler with a 30kW output, designed for both central heating and domestic hot water․ It features a compact, wall-mounted design and operates with natural gas․ The boiler achieves an ErP A rating for heating and hot water efficiency․ With a modulation ratio of 1:5, it adapts to demand, reducing energy waste․ Compatible with optional controls like programmable thermostats, it ensures precise temperature management․ Maximum operating pressure is 10 bar, with a DHW flow rate of up to 12․3 liters per minute․ The Logic Combi 30 comes with a standard 5-year parts and labor warranty, extendable to 10 years with optional premier plans; Registration with Ideal Heating is required to activate the warranty․ Terms and conditions apply, including annual servicing by a Gas Safe engineer․ Extended warranties cover repairs and replacements for faulty parts․ Dedicated customer support is available via phone or online portals, offering troubleshooting guides and technical assistance․ For more details, refer to the warranty section in the user manual or visit Ideal Heating’s official website․4․2 Dealing with Low Water Pressure
Maintenance and Servicing
5․1 Routine Maintenance Checks
5․2 Replacing Parts and Servicing Schedule
Technical Specifications and Warranty
6․1 Boiler Technical Details
6․2 Warranty Information and Support